Skip to content
Connected Inventions

Legionella Risk Prevention, Fully Packaged

One device, one simple monthly service. We deliver the FlexSense sensors, 24/7 cloud monitoring, instant alerts and automated Legionella compliance reports – with optional professional installation – so your water systems stay out of the risk zone and you can prove it.

Get the Legionella package
Legionella Risk Prevention, Fully Packaged

Everything Included. Nothing to Piece Together.

  • The device

    FlexSense battery-powered temperature & humidity meter with external water pipe probes.

  • 24/7 monitoring

    Cloud monitoring and instant alerts the moment hot or cold water leaves its safe range.

  • Automated reporting

    Monthly Legionella risk reports and audit-ready records for authorities and self-monitoring.

  • Installation (optional)

    Professional on-site installation of the device and external probes, so you’re up and running fast.

FlexSenseCONNECTED
Hot water56.4 °C · Safe

Why Continuous Temperature Monitoring Prevents Legionella

Legionella bacteria thrive in water between 20 °C and 45 °C. Growth is prevented by keeping hot water above 50 °C and cold water below 20 °C – and continuous monitoring verifies that it stays that way, around the clock.

Manual checks only give snapshots. Continuous measurement detects deviations in real time, so corrective action happens before a risk materialises – and every reading becomes documentation for authorities and internal control.

Built for the premises where it matters most:

  1. 01Hospitals and health centres
  2. 02Assisted living and care homes
  3. 03Hotels and accommodation
  4. 04Swimming halls, spas and public saunas
  5. 05Schools and universities
  6. 06Office buildings
  7. 07Public buildings
  8. 08Industrial and manufacturing facilities

One Provider. One Monthly Fee. Continuous Protection.

Device, wireless connectivity, cloud service and reporting come from a single provider as one package – no integrations to build, no separate systems to maintain.

  • Benefits for Building Owners

    Keep water systems safe and meet your legal obligations without adding work for your team.

    Demonstrate due diligence and compliance

    Reduce the risk of a costly Legionella outbreak

    Protect residents, patients, staff and visitors

    Replace manual temperature checks

    Manage multiple sites from a single dashboard

    Keep a complete history of water temperatures

    Receive automated monthly risk reports

  • Benefits for Service Providers

    For property managers and maintenance companies responsible for water systems, the package turns Legionella control into a scalable service.

    Monitor multiple customer sites remotely

    Prioritise maintenance based on real-time conditions

    Optimise routine site visits

    Generate automated compliance reports

    Improve customer service with proactive alerts

    Scale operations without proportionally increasing labour

What’s in the FlexSense Package

Measurements
Water temperature + humidity, every 60 min (configurable)
Probes
External probes on a 3 m cable, ±0.5 °C accuracy
Safe ranges
Verifies hot water stays above 50 °C and cold water below 20 °C
Alerts
Instant notifications when temperatures leave the safe range
Reporting
Automated monthly Legionella risk reports and audit-ready records
Connectivity
Wireless IoT network; no WiFi, wiring or IT integration needed
Battery
Up to 10 years battery life (replaceable)
Casing
IP44, outdoor-ready, 122 × 112 × 34 mm
Warranty
5 years
Installation
Optional professional on-site installation of device and probes

Your Monthly Legionella Risk Report

  • Temperature barrier

    How long the water system spent in the bacteria growth range of 20–50 °C.

  • Disinfection barrier

    How regularly the system reached a disinfecting temperature of 60 °C for at least 20 minutes.

  • Stagnation barrier

    How strongly conditions favoured bacteria attaching – stagnant water or a stable temperature.

  • Monthly risk class

    The three barriers combine into a Normal, Elevated or High risk rating – based on the WHO Water Safety Plan method.

Ready for the New Legionella Requirements

In Finland, the Health Protection Act (763/1994, section 19 b) requires owners and operators of priority premises – such as hospitals, care homes, hotels, swimming halls and spas – to complete a water system risk assessment and control measures by 12 January 2029, and to present the data to authorities on request. Hot water must stay at or above the 50 °C action limit (STM decree 545/2015), and cold water below 20 °C.

Similar water safety obligations apply across Europe, the UK, Australia and New Zealand. The Legionella package gives you continuous evidence that your water systems are under control – without the cost and complexity of manual compliance checks.

Safer buildings. Documented compliance. One simple service.

  • WELL
    WELL
  • LEED
    LEED
  • BREEAM
    BREEAM
  • RESET
    RESET

Our solutions are trusted by the following companies

  • Caverion
  • Lassila & Tikanoja
  • Polygon
  • Genano
  • Rapal
  • Technopolis
  • Sirkka